Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Nucl Med Commun ; 44(6): 427-433, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37038959

RESUMO

OBJECTIVE: iRENEX is a software module that incorporates scintigraphic and clinical data to interpret 99m Tc- mercaptoacetyltriglycine (MAG3) diuretic studies and provide reasons for their conclusions. Our objectives were to compare iRENEX interpretations with those of expert physicians, use iRENEX to evaluate resident performance and determine if iRENEX could improve the diagnostic accuracy of experienced residents. METHODS: Baseline and furosemide 99m Tc-MAG3 acquisitions of 50 patients with suspected obstruction (mean age ± SD, 58.7 ±â€…15.8 years, 60% female) were randomly selected from an archived database and independently interpreted by iRENEX, three expert readers and four nuclear medicine residents with one full year of residency. All raters had access to scintigraphic data and a text file containing clinical information and scored each kidney on a scale from +1.0 to -1.0. Scores ≥0.20 represented obstruction with higher scores indicating greater confidence. Scores +0.19 to -0.19 were indeterminate; scores ≤-0.20 indicated no obstruction. Several months later, residents reinterpreted the studies with access to iRENEX. Receiver operating characteristic (ROC) analysis and concordance correlation coefficient (CCC) quantified agreement. RESULTS: The CCC among experts was higher than that among residents, 0.84, versus 0.39, respectively, P  < 0.001. When residents reinterpreted the studies with iRENEX, their CCC improved from 0.39 to 0.73, P  < 0.001. ROC analysis showed significant improvement in the ability of residents to distinguish between obstructed and non-obstructed kidneys using iRENEX ( P  = 0.036). CONCLUSION: iRENEX interpretations were comparable to those of experts. iRENEX reduced interobserver variability among experienced residents and led to better agreement between resident and expert interpretations.


Assuntos
Diuréticos , Tecnécio Tc 99m Mertiatida , Humanos , Feminino , Masculino , Renografia por Radioisótopo , Cintilografia , Computadores , Compostos Radiofarmacêuticos
2.
J Nucl Cardiol ; 25(4): 1376-1386, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-28194728

RESUMO

BACKGROUND: The effective non-invasive identification of coronary artery disease (CAD) and its proper referral for invasive treatment are still unresolved issues. We evaluated our quantification of myocardium at risk (MAR) from our second generation 3D MPI/CTA fusion framework for the detection and localization of obstructive coronary disease. METHODS: Studies from 48 patients who had rest/stress MPI, CTA, and ICA were analyzed from 3 different institutions. From the CTA, a 3D biventricular surface of the myocardium with superimposed coronaries was extracted and fused to the perfusion distribution. Significant lesions were identified from CTA readings and positioned on the fused display. Three estimates of MAR were computed on the 3D LV surface on the basis of the MPI alone (MARp), the CTA alone (MARa), and the fused information (MARf). The extents of areas at risk were used to generate ROC curves using ICA anatomical findings as reference standard. RESULTS: Areas under the ROC curve (AUC) for CAD detection using MARf was 0.88 (CI = 0.75-0.95) and for MARp and MARa were, respectively 0.82 (CI = 0.69-0.92) and 0.75 (CI = 0.60-0.86) using the ≥70% stenosis criterion. AUCs for CAD localization (all vessels) using MARf showed significantly higher performance than either MARa or MARp or both. CONCLUSIONS: Using ICA as the reference standard, MAR as the quantitative parameter, and AUC to measure diagnostic performance, MPI-CTA fusion imaging provided incremental diagnostic information compared to MPI or CTA alone for the diagnosis and localization of CAD.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Angiografia Coronária , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
3.
J Nucl Cardiol ; 25(6): 1948-1957, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-28353213

RESUMO

OBJECTIVES: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. METHODS: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. RESULTS: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. CONCLUSIONS: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Eletrocardiografia , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Reprodutibilidade dos Testes
4.
Radiology ; 284(1): 200-209, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28212051

RESUMO

Purpose To determine if commonly administered doses of technetium 99m (99mTc) mertiatide (MAG3) in the range of 300-370 MBq (approximately 8-10 mCi) contribute to image interpretation and justify the resulting radiation exposure. Materials and Methods The respective institutional review boards approved this HIPAA-compliant study and waived informed consent. Baseline and furosemide 99mTc-MAG3 imaging examinations in 50 patients suspected of having renal obstruction and 48 patients suspected of having renovascular hypertension (RVH) were randomly selected from archived databases and were independently scored by three experienced readers without access to 2-second flow images. Readers were blinded to their original scores, and then they rescored each examination with access to high-activity 2-second flow images. Relative renal function was determined after a low activity (62.9 MBq ± 40.7) baseline acquisition for RVH and a high activity (303.4 MBq ± 48.1) acquisition after administration of enalaprilat. Data were analyzed by using random effects analysis of variance and mean and standard error of the mean for the difference between sets of scores and the difference between relative function measurements. Results There was no significant difference in the scores without flow images compared with blinded scores with high-activity flow images for patients suspected of having obstruction (P = .80) or RVH (P = .24). Moreover, there was no significant difference in the relative uptake measurements after administration of low and high activities (P > .99). Conclusion Administered doses of 99mTc-MAG3 in the range of 300-370 MBq (approximately 8-10 mCi) do not affect the relative function measurements or contribute to interpretation of images in patients suspected of having RVH or obstruction compared with administration of lower doses; unnecessary radiation exposure can be avoided by administering doses in the range of 37-185 MBq as recommended incurrent guidelines. © RSNA, 2017.


Assuntos
Renografia por Radioisótopo/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Obstrução da Artéria Renal/diagnóstico por imagem , Tecnécio Tc 99m Mertiatida/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
5.
J Nucl Cardiol ; 24(2): 377-391, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26791866

RESUMO

RATIONALE: 123I-mIBG planar image heart-to-mediastinum ratios effectively risk-stratify heart failure (HF) patients. The value of single-photon emission computed tomographic (SPECT) imaging for identifying increased risk of ventricular arrhythmias is less clear. This study sought to determine if findings from simultaneous interpretation of 123I-mIBG and 99mTc-tetrofosmin SPECT are predictive of arrhythmic events (ArEs). METHODS: 123I-mIBG SPECT images from 622 patients with ischemic HF were presented in standard displays alongside 99mTc-tetrofosmin images. Consensus interpretations using a 17-segment model produced summed scores. Cox proportional hazards analyses related findings to adjudicated ArEs over 2 years. RESULTS: 471 patients had images adequate for total 17-segment scoring. There were 48 ArEs (10.2%). Neither 123I-mIBG nor 99mTc-tetrofosmin SPECT summed scores were univariate predictors. On multivariate proportional hazards analysis, the 123I-mIBG SPECT score was independently predictive of ArEs (HR: 0.975, 95% CI 0.951-0.999, P = 0.042), but HR<1 indicated that risk decreased with increasing score. This occurred because patients with intermediately abnormal SPECT studies had a higher likelihood of ArEs compared to patients with extensive abnormalities. CONCLUSIONS: The presumption of a monotonic increase in ArE risk with increasing summed 123I-mIBG SPECT score may not be correct as ischemic HF patients with abnormalities of intermediate extent appear at highest risk.


Assuntos
3-Iodobenzilguanidina , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/mortalidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Causalidade , Comorbidade , Feminino , Humanos , Incidência , Internacionalidade , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/mortalidade , Prognóstico , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Taxa de Sobrevida
7.
J Nucl Cardiol ; 23(3): 425-35, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-25788403

RESUMO

BACKGROUND: The purpose of this study was to develop and validate new approaches to quantitative MIBG myocardial SPECT imaging in heart failure (HF) subjects. METHODS AND RESULTS: Quantitative MIBG myocardial SPECT analysis methods, alone and in conjunction with 99mTc-tetrofosmin perfusion SPECT, were adapted from previously validated techniques for the analysis of SPECT and PET perfusion imaging. To account for underestimation of MIBG defect severity in subjects with global reduction in uptake, a mixed reference database based on planar heart/mediastinum (H/M) ratio categories was used. Extent and severity of voxel-based defects and number of myocardial segments with significant dysinnervation (derived score ≥2) were determined. MIBG/99mTc-tetrofosmin mismatch was quantified using regions with preserved innervation as the reference for scaling 99mTc-tetrofosmin voxel maps. Quantification techniques were tested on studies of 619 ischemic (I) and 319 non-ischemic (NI) HF subjects. Using all analytical techniques, IHF subjects had significantly greater and more severe MIBG SPECT abnormalities compared with NIHF subjects. Innervation/perfusion mismatches were also larger in IHF subjects. Findings were consistent between voxel- and myocardial-segment-based quantitation methods. CONCLUSIONS: Multiple objective methods for quantitation of MIBG SPECT imaging studies provided internally consistent results for distinguishing the different patterns of uptake between IHF and NIHF subjects.


Assuntos
3-Iodobenzilguanidina , Insuficiência Cardíaca/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/complicações , Humanos , Aumento da Imagem/métodos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
8.
Nucl Med Mol Imaging ; 48(3): 216-24, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25177379

RESUMO

PURPOSE: Preclinical studies in rats showed that two of (99m)Tc(CO)3(ASMA) isomers (rac- and L-ASMA) had pharmacokinetic properties equivalent to that of (131)I-OIH, the radiopharmaceutical standard for the measurement of effective renal plasma flow. The aim of this study was to evaluate the pharmacokinetics of (99m)Tc(CO)3(ASMA) isomers in healthy human subjects. METHODS: Three ASMA ligands (rac-, L- and D-ASMA) were labeled with (99m)Tc(CO)3 using an IsoLink kit (Covidien), and each formed (99m)Tc(CO)3(ASMA) tracer was co-injected with (131)I-OIH into healthy human subjects followed by sequential imaging, plasma clearance measurements and timed urine collection. Plasma protein binding, red cell uptake and percent injected dose in the urine were determined. Urine from each group of volunteers was analyzed for metabolites by HPLC. RESULTS: Image quality was excellent with all three agents. Each (99m)Tc(CO)3(ASMA) preparation was excreted unchanged in the urine. The plasma clearance ratio ((99m)Tc(CO)3(ASMA)/(131)I-OIH) was 81 ± 3 % for D-ASMA compared to only 20 ± 4 % for L-ASMA and 37 ± 7 % for rac-ASMA; the 81 % clearance ratio for D-ASMA isomer is still ∼ 30 % higher than the (99m)Tc-MAG3/(131)I-OIH clearance ratio (∼50-60 %). Red cell uptake was similar for all three tracers (6-9 %), and all tracers had a relatively rapid renal excretion; at 3 h, the (99m)Tc(CO)3(ASMA)/(131)I-OIH urine ratio was 100 ± 3 % for D-ASMA, 80 ± 2 % for L-ASMA and 88 ± 1 % for rac-ASMA. CONCLUSIONS: The renal excretion characteristics of (99m)Tc(CO)3(D-ASMA) in humans are superior to those of the other two (99m)Tc(CO)3(ASMA) isomers studied, but are still inferior to (131)I-OIH, even though there was no difference in the clearance of two of (99m)Tc(CO)3(ASMA) isomers and (131)I-OIH in rats. The work described here demonstrates the sensitivity in in vivo biological behavior of (99m)Tc(CO)3(ASMA) isomers to their subtle structural differences.

9.
J Nucl Cardiol ; 21(5): 913-20, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24858625

RESUMO

OBJECTIVES: The purpose of this study is to assess mIBG uptake in scar border zone and its relation with ventricular arrhythmia (VA) inducibility on electrophysiology (EP) testing using I-123 mIBG SPECT and resting Tc-99m SPECT myocardial perfusion imaging (MPI). METHODS: Forty-seven patients from a previous clinical trial were retrospectively analyzed. These patients underwent I-123 mIBG and resting Tc-99m tetrofosmin SPECT, and EP testing. Twenty-eight patients were positive (EP+) and 19 patients were negative (EP-) for inducibility of sustained (>30 seconds) VA on EP testing. MPI scar extent, border zone extent, and mIBG uptake in border zone were used to predict VA inducibility on EP testing, respectively. RESULTS: There was no significant difference in scar extent between the EP+ and EP- groups. The EP+ group had significantly larger border zone and lower mIBG uptake ratio in the border zone than the EP- group. Receiver operating characteristic (ROC) curve analysis showed that the prediction accuracy for border zone extent (area under ROC = 0.75) was better than scar extent (area under ROC = 0.66). The prediction accuracy was further improved (area under ROC = 0.78), when assessing mIBG uptake in the border zone. CONCLUSION: A new tool has been developed to measure scar and border zone and to assess mIBG uptake in scar and border zone from combined I-123 MIBG SPECT and resting Tc-99m SPECT MPI. The mIBG uptake in the border zone predicted VA inducibility on EP testing with a promising accuracy.


Assuntos
3-Iodobenzilguanidina , Técnicas Eletrofisiológicas Cardíacas/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Taquicardia Ventricular/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Fibrilação Ventricular/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Prognóstico , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
J Nucl Cardiol ; 21(1): 96-108, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24185581

RESUMO

BACKGROUND: Accurate alignment between cardiac CT angiographic studies (CTA) and nuclear perfusion images is crucial for improved diagnosis of coronary artery disease. This study evaluated in an animal model the accuracy of a CTA fully automated biventricular segmentation algorithm, a necessary step for automatic and thus efficient PET/CT alignment. METHODS AND RESULTS: Twelve pigs with acute infarcts were imaged using Rb-82 PET and 64-slice CTA. Post-mortem myocardium mass measurements were obtained. Endocardial and epicardial myocardial boundaries were manually and automatically detected on the CTA and both segmentations used to perform PET/CT alignment. To assess the segmentation performance, image-based myocardial masses were compared to experimental data; the hand-traced profiles were used as a reference standard to assess the global and slice-by-slice robustness of the automated algorithm in extracting myocardium, LV, and RV. Mean distances between the automated and the manual 3D segmented surfaces were computed. Finally, differences in rotations and translations between the manual and automatic surfaces were estimated post-PET/CT alignment. The largest, smallest, and median distances between interactive and automatic surfaces averaged 1.2 ± 2.1, 0.2 ± 1.6, and 0.7 ± 1.9 mm. The average angular and translational differences in CT/PET alignments were 0.4°, -0.6°, and -2.3° about x, y, and z axes, and 1.8, -2.1, and 2.0 mm in x, y, and z directions. CONCLUSIONS: Our automatic myocardial boundary detection algorithm creates surfaces from CTA that are similar in accuracy and provide similar alignments with PET as those obtained from interactive tracing. Specific difficulties in a reliable segmentation of the apex and base regions will require further improvements in the automated technique.


Assuntos
Angiografia Coronária/métodos , Processamento Eletrônico de Dados , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Miocárdio/patologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Perfusão , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio/química , Suínos
11.
J Nucl Cardiol ; 21(1): 158-65, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24287713

RESUMO

BACKGROUND: We set out to develop normal databases and prospectively validate abnormality criteria for a low-dose Tc-99m tetrofosmin myocardial perfusion SPECT protocol using the 530c CZT camera. METHODS: All patients received 6 mCi rest/20 mCi stress doses of Tc-99m tetrofosmin. Rest and stress images were obtained over 7-9 and 5-7 minutes according to the chest size. Low-dose CT of the chest was obtained on a standalone CT scanner. Forty patients with very low likelihood (LLK) of coronary artery disease (CAD) were used to define the normal count distributions. The abnormality criteria were prospectively validated in 55 patients who had coronary angiography and in 40 patients with LLK of CAD. RESULTS: The results for quantitative non-attenuation-corrected (AC) and AC analysis and visual analysis were as follows: sensitivity of 79%, 85%, and 92% (P = NS) and specificity of 44%, 75%, and 56% (P = NS), respectively. The normalcy rates for quantitative non-AC and AC analyses and visual analysis were 95%, 98%, and 98% (P = NS). CONCLUSIONS: We have developed non-AC and AC normal databases for low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT protocol using the 530c CZT camera. The per-patient diagnostic performance of quantitative analyses is not significantly different from visual analysis by an experienced reader.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/patologia , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
12.
J Nucl Cardiol ; 20(3): 406-14, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23483457

RESUMO

BACKGROUND: The purpose of this study was to examine the relationship between myocardial uptake of (123)I-mIBG and age in older normal adult subjects. METHODS: 94 subjects (age 29-82, mean 58.5) without coronary heart disease were studied. All subjects underwent early and delayed planar and 4-hour SPECT (123)I-mIBG imaging. (123)I-mIBG uptake was quantified as heart/mediastinum ratio on planar images (H/M p) and on SPECT images (H/M s) reconstructed by filtered backprojection, ordered subsets-expectation maximization (OSEM), and OSEM with compensation for collimator septal penetration (DSP). Relationships between age and (123)I-mIBG uptake were examined by correlation analysis, t-tests, and analysis of variance. RESULTS: There was no significant correlation between age and H/M p, reflecting comparable increases in activity in the two regions of interest with age. Results on SPECT analyses were comparable, with no significant correlation between age and H/M s. Using DSP, (123)I-mIBG H/M s was significantly higher in subjects ≥70 of age compared with younger subjects. CONCLUSIONS: Both cardiac and background uptake of (123)I-mIBG increase with age in older subjects without coronary heart disease, resulting in stability of H/M results (planar and SPECT). This study suggests that prognostic analyses of quantitative (123)I-mIBG uptake in patients with heart disease do not require adjustment for patient age.


Assuntos
3-Iodobenzilguanidina , Coração/diagnóstico por imagem , Miocárdio/patologia , Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Compostos Radiofarmacêuticos , Valores de Referência
13.
Clin Nucl Med ; 38(1): 13-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23235485

RESUMO

PURPOSE: The purposes of this study were to establish reference values for renal size determined from 99mTc-MAG3 renal scintigraphy and to derive regression equations to predict normal limits. METHODS: The study population consisted of 106 subjects evaluated for kidney donation who underwent 99mTc-MAG3 renal scintigraphy. Renal length, width, and area were determined from the pixel length and area of whole-kidney regions of interest and correlated with patient sex, height, weight, body mass index, and body surface area (BSA). Reference values were obtained based on estimation of the lower and upper percentiles via quantile regression. RESULTS: The mean (SD) left and right kidney lengths was 12.2 (1.0) and 12.1 (1.0) in male and 11.9 (0.9) and 11.8 (0.9) in female patients, respectively. Sex was not a significant factor in the quantile regression models. Regression equations defining the lower and upper limits of renal length (cm) and area (cm) are as follows: left kidney length (5th percentile), 8.2+1.3×BSA; left kidney length (95th percentile), 9.1+2.3×BSA; right kidney length (5th percentile), 8.8+1.0×BSA; right kidney length (95th percentile), 11.1+1.4×BSA; left kidney area (5th percentile), 32.5+9.6×BSA; left kidney area (95th percentile), 12.6+31.7×BSA; right kidney area (5th percentile), 16.1+18.5×BSA; right kidney area (95th percentile), 32.6+22.2×BSA. CONCLUSIONS: Regression equations have been developed, which define the upper and lower limits of renal size from 99mTc-MAG3 images and may assist in the detection of unsuspected bilateral increases or decreases in renal size.


Assuntos
Rim/diagnóstico por imagem , Rim/patologia , Tecnécio Tc 99m Mertiatida , Adulto , Estatura , Índice de Massa Corporal , Peso Corporal , Feminino , Humanos , Nefropatias/diagnóstico por imagem , Masculino , Tamanho do Órgão , Cintilografia , Valores de Referência
14.
Nucl Med Commun ; 34(2): 124-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23211996

RESUMO

OBJECTIVE: Left ventricular (LV) function and dyssynchrony parameters measured from serial gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) using blinded processing had a poorer repeatability than when manual side-by-side processing was used. The objective of this study was to validate whether an automatic alignment tool can reduce the variability of LV function and dyssynchrony parameters in serial gated SPECT MPI. METHODS: Thirty patients who had undergone serial gated SPECT MPI were prospectively enrolled in this study. Thirty minutes after the first acquisition, each patient was repositioned and a gated SPECT MPI image was reacquired. The two data sets were first processed blinded from each other by the same technologist in different weeks. These processed data were then realigned by the automatic tool, and manual side-by-side processing was carried out. All processing methods used standard iterative reconstruction and Butterworth filtering. The Emory Cardiac Toolbox was used to measure the LV function and dyssynchrony parameters. RESULTS: The automatic tool failed in one patient, who had a large, severe scar in the inferobasal wall. In the remaining 29 patients, the repeatability of the LV function and dyssynchrony parameters after automatic alignment was significantly improved from blinded processing and was comparable to manual side-by-side processing. CONCLUSION: The automatic alignment tool can be an alternative method to manual side-by-side processing to improve the repeatability of LV function and dyssynchrony measurements by serial gated SPECT MPI.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo
15.
J Nucl Med Technol ; 40(4): 236-43, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23015477

RESUMO

UNLABELLED: Our objective was to design and implement a clinical history database capable of linking to our database of quantitative results from (99m)Tc-mercaptoacetyltriglycine (MAG3) renal scans and export a data summary for physicians or our software decision support system. METHODS: For database development, we used a commercial program. Additional software was developed in Interactive Data Language. MAG3 studies were processed using an in-house enhancement of a commercial program. The relational database has 3 parts: a list of all renal scans (the RENAL database), a set of patients with quantitative processing results (the Q2 database), and a subset of patients from Q2 containing clinical data manually transcribed from the hospital information system (the CLINICAL database). To test interobserver variability, a second physician transcriber reviewed 50 randomly selected patients in the hospital information system and tabulated 2 clinical data items: hydronephrosis and presence of a current stent. The CLINICAL database was developed in stages and contains 342 fields comprising demographic information, clinical history, and findings from up to 11 radiologic procedures. A scripted algorithm is used to reliably match records present in both Q2 and CLINICAL. An Interactive Data Language program then combines data from the 2 databases into an XML (extensible markup language) file for use by the decision support system. A text file is constructed and saved for review by physicians. RESULTS: RENAL contains 2,222 records, Q2 contains 456 records, and CLINICAL contains 152 records. The interobserver variability testing found a 95% match between the 2 observers for presence or absence of ureteral stent (κ = 0.52), a 75% match for hydronephrosis based on narrative summaries of hospitalizations and clinical visits (κ = 0.41), and a 92% match for hydronephrosis based on the imaging report (κ = 0.84). CONCLUSION: We have developed a relational database system to integrate the quantitative results of MAG3 image processing with clinical records obtained from the hospital information system. We also have developed a methodology for formatting clinical history for review by physicians and export to a decision support system. We identified several pitfalls, including the fact that important textual information extracted from the hospital information system by knowledgeable transcribers can show substantial interobserver variation, particularly when record retrieval is based on the narrative clinical records.


Assuntos
Bases de Dados Factuais , Informática Médica/métodos , Renografia por Radioisótopo , Técnicas de Apoio para a Decisão , Humanos , Processamento de Imagem Assistida por Computador , Médicos , Software , Tecnécio Tc 99m Mertiatida
16.
J Nucl Cardiol ; 19(1): 92-9, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22147616

RESUMO

BACKGROUND: The purpose of this study was to evaluate global quantitation of cardiac uptake on I-123 mIBG SPECT. METHODS: The study included a pilot group of 67 subjects and a validation group of 1,051 subjects. SPECT images were reconstructed by filtered backprojection, ordered subsets expectation maximization, and deconvolution of septal penetration, respectively. SPECT heart-to-mediastinum ratio (H/M) was calculated by comparing the mean counts between heart and mediastinum volumes of interest drawn on transaxial images. Receiver operating characteristic (ROC) analysis was used to assess the capability of each SPECT method to differentiate the heart disease subjects from controls in comparison with that of the planar H/M. RESULTS: In the validation group, the areas under the ROC curves were not significantly different between the SPECT and planar H/M. Order subsets expectation maximization had significantly larger area under the ROC curve than the other two SPECT methods. CONCLUSION: H/M obtained from I-123 mIBG SPECT was equivalent to the planar H/M for differentiating between subjects with normal and abnormal mIBG uptake. Global quantification of cardiac I-123 mIBG SPECT may represent a viable alternative to the planar H/M.


Assuntos
3-Iodobenzilguanidina/farmacocinética , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/metabolismo , Coração/diagnóstico por imagem , Miocárdio/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Algoritmos , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Projetos Piloto , Compostos Radiofarmacêuticos/farmacocinética , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
17.
J Nucl Med Technol ; 39(2): 131-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21565959

RESUMO

UNLABELLED: Kidney motion during dynamic renal scintigraphy can cause errors in calculated renal function parameters. Our goal was to develop and validate algorithms to detect and correct patient motion. METHODS: We retrospectively collected dynamic images from 86 clinical renal studies (42 women, 44 men), acquired using (99m)Tc-mercaptoacetyltriglycine (80 image frames [128 × 128 pixels; 3.2 mm/pixel]: twenty-four 2-s frames, sixteen 15-s frames, and forty 30-s frames). We simulated 10 types of vertical motion in each patient study, resulting in 860 image sets. Motion consisted of up or down shifts of magnitude 0.25 pixel to 4 pixels per frame and was either a gradual shift additive over multiple frames or an abrupt shift of one or more consecutive frames, with a later return to the start position. Additional horizontal motion was added to test its effect on detection of vertical motion. Original and shifted files were processed using a motion detection algorithm. Corrective shifts were applied, and the corrected and original (unshifted) images were compared pixel by pixel. Motion detected in the shifted data was also tabulated before and after correction of motion detected in the original data. A detected shift was considered correct if it was within 0.25 pixel of the simulated magnitude. Software was developed to facilitate visual review of all images and to summarize kidney motion and motion correction using linograms. RESULTS: Overall detection of simulated shifts was 99% (3,068/3,096 frames) when the existing motion in the original images was first corrected. When the original motion was not corrected, overall shift detection was 76% (2,345/3,096 frames). For image frames in which no shift was added (and original motion was not corrected), 87% (27,142/31,132 frames) were correctly detected as having no shift. When corrected images were compared with original images, calculated count recovery was 100% for all shifts that were whole-pixel magnitudes. For fractional-pixel shifts, percentage count recovery varied from 52% to 73%. Visual review suggested that some original frames exhibited true patient motion. CONCLUSION: The algorithm accurately detected motion as small as 0.25 pixel. Whole-pixel motion can be detected and corrected with high accuracy. Fractional-pixel motion can be detected and corrected, but with less accuracy. Importantly, by accurately identifying unshifted frames, the algorithm helps to prevent the introduction of errors during motion correction.


Assuntos
Rim/diagnóstico por imagem , Rim/fisiopatologia , Movimento , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tecnécio Tc 99m Mertiatida , Tomografia Computadorizada de Emissão de Fóton Único , Adulto Jovem
18.
J Nucl Cardiol ; 17(5): 811-6, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20440590

RESUMO

BACKGROUND: The purpose of this study was to establish the repeatability of left-ventricular (LV) dyssynchrony and function parameters measured from serial gated myocardial perfusion SPECT (GMPS) studies. METHODS: Thirty patients, who met standard criteria for cardiac resynchronization therapy (CRT), were prospectively enrolled. One hour after resting injection, a standard GMPS was performed, and repeated 30 minutes later after repositioning the patient. The two serial studies were processed blinded from each other by an experienced operator, and processed side-by-side by another experienced operator using iterative reconstruction, Butterworth filtering, and the Emory Cardiac Toolbox with phase analysis. Phase standard deviation, phase histogram bandwidth, LV ejection fraction, end-systolic volume, and end-diastolic volume were calculated and compared. RESULTS: All measured parameters were highly correlated (r > .90) between the serial studies without significant difference by paired t test. The variations of the parameters measured by side-by-side processing were significantly smaller than those measured by blinded processing. CONCLUSION: These results indicated high repeatability of LV dyssynchrony and function parameters when measured serially by GMPS, especially when the serial studies were processed side-by-side. The measured variations of these parameters can be used to evaluate changes in LV dyssynchrony and function measured by GMPS before and after CRT.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
19.
J Nucl Cardiol ; 17(2): 247-53, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19937169

RESUMO

OBJECTIVE: To compare the diagnostic accuracy of Rb-82 myocardial perfusion three-dimensional (3D) PET with and without prompt-gamma compensation (PGC). METHODS AND RESULTS: Retrospective, single center study of 76 patients who had rest and adenosine stress Rb-82 myocardial perfusion 3D PET. All studies were acquired using a Siemens Biograph-40 PET/CT scanner and were reconstructed with and without PGC. Fifty-seven patients (mean age 63 +/- 11 years, 26 men) had coronary angiography within 40 days of Rb-82 imaging. Nineteen patients (mean age 43 +/- 7 years, 10 men) had low likelihood of coronary artery disease (CAD). All PET images were scored by consensus of two blinded readers on a standard 5-point scale using a 17-segment left ventricular model. A normal PET test was defined as a summed stress score of less than four. Obstructive CAD at coronary angiography was used as the gold-standard and was defined as luminal stenoses > or =50% in one or more major coronary arteries. The prevalence of obstructive disease at coronary angiography was 68% (39/57). The mean summed stress score was 12 +/- 12 for PGC images and was 18 +/- 14 for non-PGC images. Sensitivity and specificity for obstructive CAD were 90% (95% CI 88-99) and 72% (95% CI 52-93) for PGC images and 95% (95% CI 88-100) and 22% (95% CI 3-41) for non-PGC images. CONCLUSION: PGC in Rb-82 3D PET improves the specificity for obstructive CAD at coronary angiography with no significant loss in sensitivity.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Miocárdio/patologia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Radioisótopos de Rubídio/química , Espalhamento de Radiação
20.
J Nucl Cardiol ; 16(6): 927-34, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19688410

RESUMO

OBJECTIVE: To compare the diagnostic performance of a new dedicated ultrafast solid-state cardiac camera (Discovery NM 530c [DNM]) with standard dual detector cameras (S-SPECT) in myocardial perfusion imaging. The primary goal was a per-patient analysis of diagnostic performance of the DNM using S-SPECT as the reference standard. METHODS AND RESULTS: In total, 168 patients underwent one-day Tc-99m tetrofosmin rest/stress myocardial perfusion SPECT. DNM and S-SPECT images were obtained with the same injected doses. The DNM camera uses an array of cadmium zinc telluride pixilated detectors and a multipinhole collimator simultaneously imaging all cardiac views with no moving parts. Rest and stress acquisition times were 4 and 2 minutes for DNM and 14 and 12 minutes for S-SPECT. Two blinded readers independently interpreted all scans on a patient level and on a vascular territory level using a standard five-point scale. Interobserver differences were resolved by a third observer. Agreement between DNM and S-SPECT for presence or absence of myocardial perfusion defects on a per-patient analysis was 91.9% and 92.5%, respectively. Correlation coefficients of rest and stress left ventricular ejection fractions were 0.87 (P < .01) and 0.90 (P < .01). CONCLUSION: The diagnostic performance of DNM is comparable to that of S-SPECT on a per-patient basis. However, superior image quality can be achieved with significantly shorter acquisition times with DNM because of improved count sensitivity and image contrast over S-SPECT.


Assuntos
Imagem de Perfusão do Miocárdio/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Israel , Imagens de Fantasmas , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...